OWNERS MANUAL
Micro TPI Field Portable Turbidimeter
HF scientific, inc.
3170 Metro Parkway
Ft. Myers, FL 33916
Phone: 239-337-2116
Fax: 239-332-7643
Manual Part No. 22666 (12/04)
Rev. 1.4
Seitenansicht 0
1 2 3 4 5 6 ... 18 19

Inhaltsverzeichnis

Seite 1

OWNERS MANUAL Micro TPI Field Portable Turbidimeter HF scientific, inc. 3170 Metro Parkway Ft.

Seite 2

Turn on the instrument by pressing the ON/OFF button continuously for 1 second. Allow 75-second warm-up period while preparing for the turbidity meas

Seite 3 - DECLARATION OF CONFORMITY

4.0 Instrument Calibration The instrument was calibrated and tested prior to leaving the factory. Therefore, it is possible to use the instrument d

Seite 4 - Table of Contents

2. While rotating the standard, observe the turbidity reading and locate the cuvette position with the lowest turbidity reading. 3. With the calibr

Seite 5 - Specifications

5.0 Troubleshooting The instrument routinely performs self-diagnostics, and will automatically generate messages to provide you with specific diagno

Seite 6 - 1.0 Overview

The following table lists the error messages and their associated meanings: Error ASSOCIATED MEANING TYPICAL CAUSE 1 Lamp failure Lamp has too lo

Seite 7

6.0 Routine Maintenance If you do not plan on leaving the instrument in the supplied carrying case, when not in use, ensure that the instrument has

Seite 8 - 2.0 Safety

6.2 Battery Replacement The instrument will periodically require new batteries to function properly. This will be indicated with a flashing batter

Seite 9 - 3.0 Normal Operation

7.0 Accessories and Replacement Parts List The items shown below are recommended accessories and replacement parts for the instrument. Accessory Ca

Seite 10 - ↵ button while

8.0 Warranty The manufacturer warrants to the original purchaser of this instrument that it will be free of defects in material and workmanship, in

Seite 11 - 4.0 Instrument Calibration

Glossary Formazin Nephelometric Units (FNU): see Nephelometric Turbidity Units Formazin Turbidity Units (FTU): see Nephelometric Turbidity Units I

Seite 13 - 5.0 Troubleshooting

DECLARATION OF CONFORMITY Application of Council Directive Standard to which Conformity is Declared: Product Safety - Tested and passed CE EN610

Seite 14

Table of Contents DECLARATION OF CONFORMITY... i Specifica

Seite 15 - 6.0 Routine Maintenance

Specifications Measurement Range 0.01 –1100 NTU/FTU Accuracy ±2% of reading or 0.01 NTU (0-500 NTU) ±3% of reading (500-1100 NTU) Resolution 0.01

Seite 16

1.0 Overview The MicroTPI (the instrument hereafter) allows you to measure turbidity in the field. This instrument was designed to meet the design

Seite 17

Figure 1: Top view of the instrument. 1.2 The Display All of the items that can appear on the display are shown in Figure 2. The display is used fo

Seite 18 - 8.0 Warranty

2.0 Safety This manual contains basic instructions that you must follow during the operation, care and maintenance of the instrument. The safety pro

Seite 19 - Glossary

3.0 Normal Operation This instrument allows you to measure the turbidity of a grab sample. The turbidity is reported in Nephelometric Turbidity Uni